Article ID: 000074147 Content Type: Troubleshooting Last Reviewed: 10/05/2020

Is there a known problem with the per pin RLC value in IBIS files generated in Intel® Quartus® Prime Pro Edition software for Intel® Stratix® 10 MX devices?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Yes, due to a known problem with Intel® Quartus® Prime Pro Edition software version 20.3 and earlier, when generating an IBIS file for Intel® Stratix® 10 MX 1650 and 2100 density devices in UF55 package with "Print per pin RLC package model with mutual coupling' option enabled, the R value per pin in the generated .ibs file is incorrect.

    Resolution

    To obtain the correct per pin RLC value for Intel Stratix 10 MX 1650 and 2100 density devices in UF55 package, download the attached file.

    This problem is scheduled to be fixed in a future release of the Intel Quartus Prime Pro Edition software.

    Related Products

    This article applies to 1 products

    Intel® Stratix® 10 MX FPGA