Article ID: 000086335 Content Type: Troubleshooting Last Reviewed: 02/14/2017

Have the Arria 10 device timing models for input paths with calibrated I/O standards been changed since the release of the Quartus Prime software version 16.1 Update 1?

Environment

  • Intel® Quartus® Prime Pro Edition
  • I O
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Yes, since the release of the Quartus® Prime software version 16.1 Update 1 the timing models for the I/O input paths have been updated for Arria® 10 devices. This affects designs that use input pins with calibrated I/O standards and either 40, 50 or 60 ohm input termination. 3V I/Os are not impacted because they do not support calibrated terminations. 

    Resolution

    If design uses the affected I/O configrations, rerun the TimeQuest Timing Analyzer on the Quartus Prime software version 16.1 Update 2 or later. For External Memory Interface (EMIF) IP, regeneration of IP is required. If there are timing violations, run the Fitter in the Quartus Prime software version 16.1 Update 2 or later to close timing on the design.

    Related Products

    This article applies to 1 products

    Intel® Arria® 10 FPGAs and SoC FPGAs