Article ID: 000086588 Content Type: Troubleshooting Last Reviewed: 03/08/2022

Is there any problem when raw data file is added in a programming file using Block Address Mode?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    Yes. Due to a problem in the Programming File Generator of the Intel® Quartus® Prime Pro Edition Software version 21.2, you will not be able to add raw data files (e.g. .bin or .hex) with Block option in the Address Mode. 

    Resolution

    To work around this problem, use the Auto or the Start option in the Address Mode to add raw data file.
    This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 21.3.

    Also, see the following KDB which contains a patch for the Intel® Quartus® Prime Pro Edition Software 21.2: Why does my Intel® Stratix® 10 design fail to boot/read from QSPI when using the Intel® Quartus® Prime Pro software version 21.1 or 21.2 to create full flash images such as.JIC /.RPD files? 