Article ID: 000091463 Content Type: Compatibility Last Reviewed: 05/25/2023

Can I re-run the Assembler to generate the SRAM Object File (SOF) for Intel® Stratix® 10 and Intel Agilex® 7 FPGAs when changing the configuration scheme from Active Serial to Avalon® streaming x8, x16 or x32 without recompiling the full design?

Environment

  • Intel® Quartus® Prime Pro Edition
  • Intel® FPGA Programming Software
  • UNIX family*, Windows® 10 family

    BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    No, re-running the Assembler in the Intel® Quartus® Prime Pro Edition Software is not sufficient because Active Serial (AS) x4 and Avalon® streaming x8, x16, x32 configuration schemes have different sets of reserved configuration pins in the Intel® Stratix® 10 and Intel Agilex® 7 FPGAs.

     

     

    Resolution

    Recompile the full design using the Intel® Quartus® Prime Pro Edition Software according to the respective FPGA configuration schemes.

    Related Products

    This article applies to 2 products

    Intel Agilex® 7 FPGAs and SoC FPGAs
    Intel® Stratix® 10 FPGAs and SoC FPGAs